石油类污染场地地下水抽水过程水质变化成因
ANALYSIS OF GROUNDWATER QUALITY CHANGING IN PETROLEUM-CONTAMINATED SITE DURING PUMPING
-
摘要: 在某石油类污染场地抽水试验过程中对地下水五项常规水质指标进行了连续监测.通过对指标的相关性和主成分分析,基于抽水、弥散试验,揭示了该场地抽水过程中水质变化的原因,探讨了以水质指标描述石油类污染场地地下水净化的方法.结果显示,水质变化是由昼夜水温变化、抽水和生化耗氧作用三者引起.其中,水温变化是由昼夜变化引起;电导率减小是抽水作用使导电粒子减少的结果;溶解氧(DO)主要受生化耗氧作用和水温引起的氧溶解度变化的影响;pH受水温引起的水的离子积常数变化、抽水作用引起的酸碱性物质减少和生化耗氧作用产生CO2的影响;氧化还原电位(ORP)受抽水作用引起的反应物质浓度减少和水温变化引起的地下水即时溶解氧变化的影响.其中,pH与DO的关系主要是生化耗氧作用的直接结果.温度、电导率、DO、pH和ORP五项指标可提取为地下水自净速率和净化能力两个主成分,描述地下水净化.Abstract: Five conventional indices of groundwater quality were monitored continuously in a petroleum-contaminated site during a pumping test. Based on the pumping and dispersion test, the causes of changes in water quality in the site were revealed through correlation and principal component analyses, and a method of describing the purification of petroleum-contaminated groundwater was discussed. The research shows that the changes in groundwater quality are the combined results of day-and-night water temperature change, pumping effect and bio-chemical oxygen effect. The water temperature change results from Day-and-Night change; The reduction of conductivity arises from decreased conductive particles caused by pumping effect; DO change is mainly affected by bio-chemical oxygen effect and oxygen solubility variation due to temperature change; pH varies with water ionic product constant change caused by water temperature, acid-base substance decrease by pumping effect and CO2 production by bio-chemical oxygen effect; ORP is affected by low concentration of reactant caused by pumping effect, and instant DO change by temperature change. The relationship between DO and pH is greatly influenced by the bio-chemical reaction. The five indices (temperature, conductivity, DO, pH and ORP) can be considered as two principal components of self-purification rate and purification capability to describe the purification of groundwater.
-
Key words:
- petroleum-contaminated /
- preferential flow /
- conductivity /
- pH /
- ORP /
- DO /
- purification /
- instant DO
-
[1] 蔡五田.我国污染场地调查评价的基本程序、问题及对策[J]. 水文地质工程地质,2008,35(增刊):41-45 [2] Jerker Jarsjoe, Marti Bayer-Raich, Thomas Ptak. Monitoring groundwater contamination and delineating source zones at industrial sites: Uncertainty analyses using integral pumping tests [J]. Journal of Contaminant Hydrology, 2005, 79:107-134 [3] 地质矿产部水文地质工程地质技术方法研究所.水文地质手册[M]. 北京:地质出版社,1985 [4] 沈照理,刘光亚,杨成田,等.水文地质学(第二版)[M]. 北京:科学出版社,1991 [5] 宇传华.SPSS与统计分析(第一版)[M]. 北京:电子工业出版社,2007:85-88,110-112 ,243-248,491-507
[6] [7] 王红云.环境化学(第一版)[M]. 北京:化学工业出版社,2004:70-76 [8] 董胜年.湖泊中水下植物光合作用对溶解氧和pH值的影响[J].中国环境监测,1997,13(5):48-50 [9] 卢迎春,王燕,王菊香.水样中溶解氧、化学需氧量、生物耗氧量的测定注意事项[J]. 光谱实验室,2008,25(3):387-389 [10] 贾振邦,赵智杰,常原飞,等.辽河水体中COD 的变化特征[J]. 环境化学,2004,23(4):435-440 [11] 李学美,赵子军,崔亚莉,等.盘山山前地下水与矿泉水污染成因分析[J]. 水文地质工程地质,2008(1):112-116 [12] 李卫红,陈永金,张保华,等.塔里木河中游地下水化学变化及其影响因素[J]. 环境化学,2011,30(2):459-465 [13] 高大文,王淑莹,彭永臻,等.温度变化对DO 和ORP 作为过程控制参数的影响[J]. 环境科学,2003,24(1):63-69
计量
- 文章访问数: 971
- HTML全文浏览数: 923
- PDF下载数: 334
- 施引文献: 0