紫外活化过硫酸盐/甲酸体系还原水中Cr(Ⅵ)机理及影响因素

秦宝雨, 唐海, 严律, 苏春景. 紫外活化过硫酸盐/甲酸体系还原水中Cr(Ⅵ)机理及影响因素[J]. 环境工程学报, 2019, 13(9): 2121-2129. doi: 10.12030/j.cjee.201812139
引用本文: 秦宝雨, 唐海, 严律, 苏春景. 紫外活化过硫酸盐/甲酸体系还原水中Cr(Ⅵ)机理及影响因素[J]. 环境工程学报, 2019, 13(9): 2121-2129. doi: 10.12030/j.cjee.201812139
QIN Baoyu, TANG Hai, YAN Lü, SU Chunjing. Mechanism and influencing factors of aqueous Cr(Ⅵ) reduction by carbon dioxide anion radical based on the UV-activated sodium persulfate/formic acid system[J]. Chinese Journal of Environmental Engineering, 2019, 13(9): 2121-2129. doi: 10.12030/j.cjee.201812139
Citation: QIN Baoyu, TANG Hai, YAN Lü, SU Chunjing. Mechanism and influencing factors of aqueous Cr(Ⅵ) reduction by carbon dioxide anion radical based on the UV-activated sodium persulfate/formic acid system[J]. Chinese Journal of Environmental Engineering, 2019, 13(9): 2121-2129. doi: 10.12030/j.cjee.201812139

紫外活化过硫酸盐/甲酸体系还原水中Cr(Ⅵ)机理及影响因素

    作者简介: 秦宝雨(1993—),男,硕士研究生。研究方向:水污染治理与资源化利用。E-mail:1209368573@qq.com
    通讯作者: 唐海(1976—),男,硕士,教授。研究方向:水污染治理与资源化利用。E-mail:tanghai@ahpu.edu.cn
  • 基金项目:
    安徽省自然科学基金资助项目(1608085ME118);安徽省优秀人才基金资助项目(gxyqZD2016120)
  • 中图分类号: X703

Mechanism and influencing factors of aqueous Cr(Ⅵ) reduction by carbon dioxide anion radical based on the UV-activated sodium persulfate/formic acid system

    Corresponding author: TANG Hai, tanghai@ahpu.edu.cn
  • 摘要: 采用紫外活化过硫酸盐/甲酸体系所产生的还原性二氧化碳阴离子自由基(${\rm{CO}}_2^{\cdot -}$),研究了水溶液中高浓度Cr(Ⅵ)的去除效果;使用电子自旋共振(ESR)技术,鉴定识别了体系中产生的活性自由基;分析了体系的活化机理及其对Cr(Ⅵ)的还原机制;考察了过硫酸盐投加量、初始pH、腐殖酸、无机阴离子(Cl${\rm{HCO}}_3^{-} $${\rm{NO}}_3^{-} $)及初始Cr(Ⅵ)浓度等对Cr(Ⅵ)去除的影响。结果表明:紫外活化过硫酸盐/甲酸体系可以有效还原Cr(Ⅵ),当过硫酸钠与甲酸浓度分别为20 mmol·L−1和40 mmol·L−1,未调初始pH为2.4时,初始浓度为200 mg·L−1 Cr(VI)在50 min内基本完全可被还原;此外,Cr(Ⅵ)还原去除率随过硫酸盐浓度升高而增强,在酸性条件下(pH=2.4),体系对Cr(Ⅵ)的还原效率最高,随着pH的增大,还原效率明显降低。进一步研究表明,Cl${\rm{HCO}}_3^{-} $${\rm{NO}}_3^{-} $对Cr(Ⅵ)的还原都存在抑制作用,在相同浓度下,其抑制程度分别为${\rm{HCO}}_3^{-} $>${\rm{NO}}_3^{-} $>Cl,腐殖酸也对Cr(Ⅵ)的去除存在抑制作用。紫外活化过硫酸盐/甲酸体系还原Cr(Ⅵ)过程符合零级反应动力学方程,其动力学常数为78.467 μmol·(L·min)−1。本研究结果为Cr(Ⅵ)废水的处理提供了一种高效的还原新技术。
  • 加载中
  • 图 1  UV、UV/PS、UV/PS/HCOOH还原Cr(Ⅵ)

    Figure 1.  Reduction of Cr(Ⅵ) by UV, UV/PS and UV/PS/HCOOH

    图 2  UV/PS/FA反应体系ESR表征谱图

    Figure 2.  ESR spectra for UV/PS/FA system

    图 3  UV/PS/FA体系还原Cr(Ⅵ)机理

    Figure 3.  Mechanism of Cr(Ⅵ) reduction by UV/PS/FA system

    图 4  PS浓度对Cr(Ⅵ)还原效果的影响

    Figure 4.  Effect of PS dosage on Cr(Ⅵ) reduction

    图 5  初始pH对Cr(Ⅵ)去除率的影响

    Figure 5.  Effect of initial pH on Cr(Ⅵ) removal efficiency

    图 6  Cl${\rm{HCO}}_3^{-} $${\rm{NO}}_3^{-} $浓度对Cr(Ⅵ)还原去除效果的影响

    Figure 6.  Effects of Cl, ${\rm{HCO}}_3^{-} $ and ${\rm{NO}}_3^{-} $ on Cr(Ⅵ) removal efficiency

    图 7  腐植酸对Cr(Ⅵ)降解的影响

    Figure 7.  Effect of humic acid on Cr(Ⅵ) reduction

    图 8  Cr(Ⅵ)初始浓度的影响

    Figure 8.  Effects of initial concentration on Cr(Ⅵ) reduction

    图 9  不同初始浓度下Cr(Ⅵ)还原过程的零级动力学分析

    Figure 9.  Zero-order kinetics of Cr(Ⅵ) reduction with different initial concentrations

    表 1  不同初始浓度下Cr (VI) 的还原反应速率常数

    Table 1.  Zero-order rate constant of Cr (VI) reduction with different initial concentrations

    Cr(VI)初始浓度/
    (mg·L−1)
    k/(μmol·(L·min)−1) R2
    200 78.467 0.981
    240 70.156 0.986
    300 56.577 0.985
    Cr(VI)初始浓度/
    (mg·L−1)
    k/(μmol·(L·min)−1) R2
    200 78.467 0.981
    240 70.156 0.986
    300 56.577 0.985
    下载: 导出CSV
  • [1] CHAKRABARTI S, CHAUDHURI B, BHATTACHARJEE S, et al. Photo-reduction of hexavalent chromium in aqueous solution in the presence of zinc oxide as semiconductor catalyst[J]. Chemical Engineering Journal, 2009, 153(1): 86-93.
    [2] BRAHIMI R, BESSEKHOUAD Y, NASRALLAH N, et al. Visible light ${\rm{CrO}}_4^{2-} $ reduction using the new CuAlO2/CdS hetero-system[J]. Journal of Hazardous Materials, 2012, 219-220(6): 19-25.
    [3] MITRA P, SARKAR D, CHAKRABARI S, et al. Reduction of hexa-valent chromium with zero-valent iron: Batch kinetic studies and rate model[J]. Chemical Engineering Journal, 2011, 171(1): 54-60. doi: 10.1016/j.cej.2011.03.037
    [4] WU P X, LI S Z, JU L T, et al. Mechanism of the reduction of hexavalent chromium by organo-montmorillonite supported iron nanoparticles[J]. Journal of Hazardous Materials, 2012, 219-220(6): 283-288.
    [5] BALAN C, VOLF I, BILBA D. Chromium (VI) removal from aqueous solutions by purolite base anion-exchange resins with gel structure[J]. Chemical Industry and Chemical Engineering Quarterly, 2013, 19(4): 615-628. doi: 10.2298/CICEQ120531095B
    [6] CHEN S S, LI C W, HSU H D, et al. Concentration and purification of chromate from electroplating wastewater by two-stage electrodialysis processes[J]. Journal of Hazardous Materials, 2009, 161(2): 1075-1080.
    [7] SU C, LUDWING R D. Treatment of hexavalent chromium in chromite ore processing solid waste using a mixed reductant solution of ferrous sulfate and sodium dithionite[J]. Environmental Science and Technology, 2005, 39(16): 6208-6216. doi: 10.1021/es050185f
    [8] TACHIKAWA T, TOJO S, FUJITSUKA M, et al. Direct observation of the one-electron reduction of methyl viologen mediated by the CO2 radical anion during TiO2 photocatalytic reactions[J]. Langmuir, 2004, 20(22): 9441-9444. doi: 10.1021/la048100w
    [9] XU M H, GU X G, LU S G, et al. Degradation of carbon tetrachloride in thermally activated persulfate system in the presence of formic acid[J]. Frontiers of Environmental Science and Engineering, 2016, 286(3): 1-9.
    [10] JIANG W C, TANG P, LU S G, et al. Enhanced reductive degradation of carbon tetrachloride by carbon dioxide radical anion-based sodium percarbonate/Fe(II)/formic acid system in aqueous solution[J]. Frontiers of Environmental Science and Engineering, 2018, 12(2): 6-15. doi: 10.1007/s11783-017-0987-6
    [11] BERKOVIC A M, GONZALEZ M C, RUSSO N, et al. Reduction of mercury(II) by the carbon dioxide radical anion: A theoretical and experimental investigation[J]. Journal of Physical Chemistry A, 2010, 114(49): 12845-12850. doi: 10.1021/jp106035m
    [12] FAN L, ZHOU A L, ZHONG L R, et al. Photoinduced reduction of high concentration Hg(II) to Hg2Cl2 from acid wastewater with the presence of fulvic acid under anaerobic conditions[J]. Chemosphere, 2018, 198: 13-20. doi: 10.1016/j.chemosphere.2018.01.123
    [13] ROSSO J A, BERTOLOTTI S G, BRAUN A M, et al. Reactions of carbon dioxide radical anion with substituted benzenes[J]. Journal of Physical Organic Chemistry, 2010, 14(5): 300-309.
    [14] REN H J, HOU Z M, HAN X, et al. Highly reductive radical ${\rm{CO}}_2^{\cdot-} $ deriving from a system with ${\rm{SO}}_4^{\cdot-} $ and formate anion: Implication for reduction of Cr(VI) from wastewater[J]. Chemical Engineering Journal, 2017, 309: 638-645. doi: 10.1016/j.cej.2016.10.071
    [15] JIANG W C, TANG P, LU S G, et al. Comparative studies of H2O2/Fe(II)/formic acid, sodium percarbonate/Fe(II)/formic acid and calcium peroxide/Fe(II)/formic acid processes for degradation performance of carbon tetrachloride[J]. Chemical Engineering Journal, 2018, 344: 453-461. doi: 10.1016/j.cej.2018.03.092
    [16] GONZALEZ M C, BRAUN A M. VUV photolysis of aqueous solutions of nitrate and nitrite[J]. Research on Chemical Intermediates, 1995, 21(8/9): 837-859.
    [17] IMOBERDORF G, MOHSENI M. Degradation of natural organic matter in surface water using vacuum-UV irradiation[J]. Journal of Hazardous Materials, 2011, 186(1): 240-246. doi: 10.1016/j.jhazmat.2010.10.118
    [18] BUXTON G V, GREENSTOCK C L, HELMAN W P, et al. Critical view of rate constants for reactions of hydrated electrons, hydrogen atoms and hydroxyl radicals (·OH/·O) in aqueous solution[J]. Journal of Physical and Chemical Reference Data, 1988, 17(2): 513-886. doi: 10.1063/1.555805
    [19] MOUSSAVI G, HOSSAINI H, JAFARI S J, et al. Comparing the efficacy of UVC, UVC/ZnO and VUV processes for oxidation of organophosphate pesticides in water[J]. Journal of Photochemistry and Photobiology A: Chemistry, 2014, 290(1): 86-93.
    [20] LIU X W, ZHONG J E, FANG L, et al. Trichloroacetic acid reduction by an advanced reduction process based on carboxyl anion radical[J]. Chemical Engineering Journal, 2016, 303: 56-63. doi: 10.1016/j.cej.2016.05.130
    [21] VILLAMENA F A, LOCIGNO E J, ROCKENBAUER A, et al. Theoretical and experimental studies of the spin trapping of inorganic radicals by 5, 5-dimethyl-1-pyrroline N-oxide (DMPO). 2. Carbon dioxide radical anion[J]. Journal of Physical Chemistry A, 2006, 110(49): 13253-13258. doi: 10.1021/jp064892m
    [22] XIE P C, MA J, LIU W, et al. Impact of UV/persulfate pretreatment on the formation of disinfection byproducts during subsequent chlorination of natural organic matter[J]. Chemical Engineering Journal, 2015, 269: 203-211. doi: 10.1016/j.cej.2015.01.043
    [23] DENG J, SHAO Y S, GAO N Y, et al. Degradation of the antiepileptic drug carbamazepine upon different UV-based advanced oxidation processes in water[J]. Chemical Engineering Journal, 2013, 222(2): 150-158.
    [24] HASEGAWA K, NETA P. Rate constants and mechanisms of reaction of Cl2 radicals[J]. Journal of Physical Chemistry, 1978, 82(8): 854-857. doi: 10.1021/j100497a003
    [25] XU M H, GU X G, LU S G, et al. Degradation of carbon tetrachloride in thermally activated persulfate system in the presence of formic acid[J]. Frontiers of Environmental Science and Engineering, 2016, 286(3): 438-446.
    [26] NETA P, HUIE R E. Rate constants for reactions of nitrogen oxide (NO3) radicals in aqueous solutions[J]. Meat Technology, 1986, 90(19): 4644-4648.
    [27] EXNER M, HERRMANN H, ZELLNER R. Rate constants for the reactions of the NO3 radical with HCOOH/HCOO and CH3COOH/CH3COO in aqueous solution between 278 and 328 K[J]. Journal of Atmospheric Chemistry, 1994, 18(4): 359-378. doi: 10.1007/BF00712451
    [28] DRAGANIC Z D, NEGRON-MENDOZA A, SEHESTED K, et al. Radiolysis of aqueous solutions of ammonium bicarbonate over a large dose range[J]. International Journal of Radiation Applications and Instrumentation Part C: Radiation Physics and Chemistry, 1991, 38(3): 317-321. doi: 10.1016/1359-0197(91)90100-G
    [29] PADMAJA S, NETA P, HUIE R E. Rate constants for some reactions of inorganic radicals with inorganic ions. Temperature and solvent dependence[J]. International Journal of Chemical Kinetics, 2010, 25(6): 445-455.
    [30] HALL E S, PACKHAM R F. Coagulation of organic color with hydrolyzing coagulants[J]. Journal American Water Works Association, 1965, 57(9): 1149-1166. doi: 10.1002/j.1551-8833.1965.tb01506.x
    [31] LIU S, LIM M, FABRIS R, et al. Removal of humic acid using TiO2 photocatalytic process: Fractionation and molecular weight characterisation studies[J]. Chemosphere, 2008, 72(2): 263-271. doi: 10.1016/j.chemosphere.2008.01.061
    [32] WANG S L, CHEN C C, TZOU Y M, et al. A mechanism study of light-induced Cr(VI) reduction in an acidic solution[J]. Journal of Hazardous Materials, 2009, 164(1): 223-228. doi: 10.1016/j.jhazmat.2008.07.145
  • 加载中
图( 9) 表( 1)
计量
  • 文章访问数:  4573
  • HTML全文浏览数:  4573
  • PDF下载数:  68
  • 施引文献:  0
出版历程
  • 收稿日期:  2018-12-20
  • 录用日期:  2019-03-27
  • 刊出日期:  2019-09-01
秦宝雨, 唐海, 严律, 苏春景. 紫外活化过硫酸盐/甲酸体系还原水中Cr(Ⅵ)机理及影响因素[J]. 环境工程学报, 2019, 13(9): 2121-2129. doi: 10.12030/j.cjee.201812139
引用本文: 秦宝雨, 唐海, 严律, 苏春景. 紫外活化过硫酸盐/甲酸体系还原水中Cr(Ⅵ)机理及影响因素[J]. 环境工程学报, 2019, 13(9): 2121-2129. doi: 10.12030/j.cjee.201812139
QIN Baoyu, TANG Hai, YAN Lü, SU Chunjing. Mechanism and influencing factors of aqueous Cr(Ⅵ) reduction by carbon dioxide anion radical based on the UV-activated sodium persulfate/formic acid system[J]. Chinese Journal of Environmental Engineering, 2019, 13(9): 2121-2129. doi: 10.12030/j.cjee.201812139
Citation: QIN Baoyu, TANG Hai, YAN Lü, SU Chunjing. Mechanism and influencing factors of aqueous Cr(Ⅵ) reduction by carbon dioxide anion radical based on the UV-activated sodium persulfate/formic acid system[J]. Chinese Journal of Environmental Engineering, 2019, 13(9): 2121-2129. doi: 10.12030/j.cjee.201812139

紫外活化过硫酸盐/甲酸体系还原水中Cr(Ⅵ)机理及影响因素

    通讯作者: 唐海(1976—),男,硕士,教授。研究方向:水污染治理与资源化利用。E-mail:tanghai@ahpu.edu.cn
    作者简介: 秦宝雨(1993—),男,硕士研究生。研究方向:水污染治理与资源化利用。E-mail:1209368573@qq.com
  • 安徽工程大学生物与化学工程学院,芜湖 241000
基金项目:
安徽省自然科学基金资助项目(1608085ME118);安徽省优秀人才基金资助项目(gxyqZD2016120)

摘要: 采用紫外活化过硫酸盐/甲酸体系所产生的还原性二氧化碳阴离子自由基(${\rm{CO}}_2^{\cdot -}$),研究了水溶液中高浓度Cr(Ⅵ)的去除效果;使用电子自旋共振(ESR)技术,鉴定识别了体系中产生的活性自由基;分析了体系的活化机理及其对Cr(Ⅵ)的还原机制;考察了过硫酸盐投加量、初始pH、腐殖酸、无机阴离子(Cl${\rm{HCO}}_3^{-} $${\rm{NO}}_3^{-} $)及初始Cr(Ⅵ)浓度等对Cr(Ⅵ)去除的影响。结果表明:紫外活化过硫酸盐/甲酸体系可以有效还原Cr(Ⅵ),当过硫酸钠与甲酸浓度分别为20 mmol·L−1和40 mmol·L−1,未调初始pH为2.4时,初始浓度为200 mg·L−1 Cr(VI)在50 min内基本完全可被还原;此外,Cr(Ⅵ)还原去除率随过硫酸盐浓度升高而增强,在酸性条件下(pH=2.4),体系对Cr(Ⅵ)的还原效率最高,随着pH的增大,还原效率明显降低。进一步研究表明,Cl${\rm{HCO}}_3^{-} $${\rm{NO}}_3^{-} $对Cr(Ⅵ)的还原都存在抑制作用,在相同浓度下,其抑制程度分别为${\rm{HCO}}_3^{-} $>${\rm{NO}}_3^{-} $>Cl,腐殖酸也对Cr(Ⅵ)的去除存在抑制作用。紫外活化过硫酸盐/甲酸体系还原Cr(Ⅵ)过程符合零级反应动力学方程,其动力学常数为78.467 μmol·(L·min)−1。本研究结果为Cr(Ⅵ)废水的处理提供了一种高效的还原新技术。

English Abstract

  • 铬是一种易致癌、致突变和高毒性的环境污染物[1],环境中铬含量主要来自于电镀、冶金和制革行业等工业活动废水的排放[2]。铬主要为Cr(Ⅲ)和Cr(Ⅵ),Cr(Ⅲ)可以通过简单加碱沉淀的方法予以去除。相较而言,Cr(Ⅵ)毒性是Cr(Ⅲ)的100倍,且高迁移性使得Cr(Ⅵ)更容易在生物体和人体中积累,对生态环境及人体健康造成了严重的威胁[3-4]。当前含铬废水的处理方法主要有离子交换法[5]、膜分离法[6]和化学还原法[7]等,然而大量实践表明,这些处理方法仍然存在处理费用高和较严重的二次污染问题。目前,高毒性的Cr(Ⅵ)向低毒性的Cr(Ⅲ)转化的高效还原方法,由于降低了其对环境的危害,已成为是含铬废水处理的研究热点之一。高级还原技术(ARPs)是在高级氧化技术(AOPs)基础上发展起来的,区别在于前者可产生还原性自由基,包括水合电子(${\rm{e}}_{\rm{aq}}^{-} $)、原生态氢(H · )和二氧化碳阴离子自由基(${\rm{CO}}_2^{\cdot -} $)等。近年来,对于${\rm{CO}}_2^{\cdot -} $的研究屡有报道[8-9]${\rm{CO}}_2^{\cdot -} $被证实是一种强还原性自由基,氧化还原电位为−1.9 V[10],目前有研究[11-12]表明,${\rm{CO}}_2^{\cdot -} $可以与Hg(Ⅱ)、取代苯化合物[13]、四氯化碳[10]、Cr(Ⅵ)[14]等反应,且均具有较好的还原去除效果。有研究[13]表明,${\rm{CO}}_2^{\cdot -} $产生的主要方法为向AOPs体系中加入甲酸或者甲酸盐,使含有${\rm{SO}}_4^{\cdot -} $、HO · 的氧化性体系转化为还原性体系(如式(1)和式(2)所示),进而对高氧化态的污染物表现出明显的去除效果。JIANG等[15]向过碳酸钠/Fe(Ⅱ)和过氧化钙/Fe(Ⅱ)类芬顿体系中加入HCOOH之后,可以明显降解四氯化碳。REN等[14]在Cr(Ⅵ)、Na2S2O8和HCOO初始浓度分别为50、30和30 mmol·L−1,反应温度为70 ℃条件下,热活化Na2S2O8/HCOO体系,反应240 min之后,Cr(Ⅵ)去除率可以达到99%。

    本研究采用紫外(UV)活化过硫酸盐(PS)/甲酸(FA)体系还原高浓度Cr(Ⅵ),利用UV、UV/PS和UV/PS/FA体系对Cr(Ⅵ)还原效果的对比,结合电子自旋共振(ESR)对体系中产生的主要自由基进行了检测分析,研究了UV/PS/FA体系的活化机制及其对Cr(Ⅵ)的还原机制,并考察体系主要反应条件以及复杂水体环境中天然有机物(NOM)、无机阴离子对体系还原Cr(Ⅵ)的影响,以期为高浓度Cr(Ⅵ)还原提供新型高效的、实用性较强的均相光催化处理方法。

    • 丙酮(C3H6O)、硝酸钠(NaNO3)、氯化钠(NaCl)、碳酸氢钠(NaHCO3)、硫酸(H2SO4)、磷酸(H3PO4)、氢氧化钠(NaOH)、甲酸(HCOOH)、二苯碳酰二肼(C13H14N4O)、过硫酸钠(Na2S2O8)均为分析纯;重铬酸钾(K2Cr2O7)为优级纯;腐植酸(黄腐酸FA≥90%)。

      紫外分光光度计(TU-1901,北京普析通用仪器有限责任公司)、光催化反应仪(PL-02,北京普林塞斯科技有限公司)、pH计(PHS-3C,上海天达仪器有限公司)、ESR检测仪(A300,布鲁克)。

    • 用重铬酸钾和去离子水配置模拟不同浓度的Cr(Ⅵ)废水。采用石英玻璃圆底试管作为反应瓶(V=50 mL),先将一定浓度的PS、FA和模拟废水取至反应瓶混合均匀,置于光催化反应仪里,开启磁力搅拌(400 r·min−1)和紫外光源(P=500 W)进行反应(预开启紫外灯管30 min保证光强稳定),按照既定时间取样分析,每组实验另外设置2个平行实验组。

      Cr(Ⅵ)含量采用二苯碳酰二肼分光光度法(GB 7467-1987)测定;采用ESR进行检测分析主要自由基种类,ESR检测条件:中心磁场为350.00 mT;扫描宽度为15.00 mT;扫描时间为30.00 s;微波功率为3.99 mW;调制幅度为0.10 mT;转化时间为40.00 s。

    • 在Cr(Ⅵ)初始浓度为200 mg·L−1条件下,分别对比了单独UV、UV/PS和UV/PS/FA体系对Cr(Ⅵ)的还原效率,实验结果如图1所示。由图1可知,当PS和FA分别为20 mmol·L−1和40 mmol·L−1,初始pH为2.4(未调节),单独UV和UV/PS体系在50 min内对Cr(Ⅵ)没有还原去除效果;当向UV/PS体系中加入FA之后,在50 min内Cr(Ⅵ)的去除率高达100%。由此可见,UV/PS/FA体系对高浓度Cr(Ⅵ)具有很好的去除效果。

      有研究表明,水分子在真空紫外(VUV,λ=185 nm)照射的条件下能够产生具有还原性的原生态氢(H · )和水合电子(${\rm{e}}_{\rm{aq}}^{-} $)[16-19],见式(3)~式(5)。为避免H · 和${\rm{e}}_{\rm{aq}}^{-} $对本体系带来的干扰,实验所用紫外光波长范围为200~350 nm,故单独UV对Cr(Ⅵ)不存在还原效果。UV活化PS过程中会产生${\rm{SO}}_4^{\cdot-} $和HO · ,加入FA之后,Cr(Ⅵ)去除效果明显增强,这是由于FA可以与${\rm{SO}}_4^{\cdot-} $反应产生${\rm{CO}}_2^{\cdot-} $,通过${\rm{CO}}_2^{\cdot-} $与Cr(Ⅵ)的相互作用,进而高效还原Cr(Ⅵ)为Cr(Ⅲ)。

    • 为了进一步探明UV/PS/FA的活化机制及对Cr(Ⅵ)的还原机理,以DMPO为自由基捕获剂,采用ESR对体系中的自由基进行了检测分析。在PS浓度为20 mmol·L−1条件下,通过改变FA和Cr(Ⅵ)的浓度,以UV照射15 min所捕获的自由基信号峰强度为依据,考察了自由基信号强度与FA浓度、Cr(Ⅵ)浓度之间的变化关系,结果如图2所示。由ESR表征结果可知,图2(a)~图2(c)均出现了明显且强度相同的DMPO-${\rm{CO}}_2^{\cdot-} $加合物信号峰,与LIU等[20]和VILLAMENA等[21]报道的DMPO-${\rm{CO}}_2^{\cdot-} $加合物峰值相一致,从而证实了UV/PS/FA体系确实可以产生${\rm{CO}}_2^{\cdot-} $。通过比较图2(a)图2(b)可知,在没有Cr(Ⅵ)干扰的条件下,FA浓度由10 mmol·L−1上升至40 mmol·L−1时,UV/PS/FA体系中出现的DMPO-${\rm{CO}}_2^{\cdot-} $加合物信号峰强度得到明显提高,这表明升高FA浓度可以提高${\rm{CO}}_2^{\cdot-} $产率,证明FA直接参与了${\rm{CO}}_2^{\cdot-} $的生成反应。由图2(b)图2(c)可以看出,UV/PS/FA体系中有Cr(Ⅵ)存在时,DMPO-${\rm{CO}}_2^{\cdot-} $加合物信号峰强度明显减弱,这说明体系中产生的${\rm{CO}}_2^{\cdot-} $可以与Cr(Ⅵ)发生反应,并将Cr(Ⅵ)还原去除,初步推断反应机理如图3所示。

    • 当初始Cr(Ⅵ)浓度为200 mg·L−1,FA浓度为40 mmol·L−1,PS浓度为10~25 mmol·L−1时,反应在60 min内,Cr(Ⅵ)去除率的变化情况如图4所示。从图4可以看出,当PS浓度为10 mmol·L−1时,在40 min内Cr(Ⅵ)去除率仅为35.2%;当PS增加为25 mmol·L−1时,Cr(Ⅵ)去除率提高至100%,PS对Cr(Ⅵ)的还原具有明显的促进效果。导致上述结果的主要原因是:随着PS浓度的增加,体系可以产生更多的${\rm{SO}}_4^{\cdot-} $[22],而随着${\rm{SO}}_4^{\cdot-} $的增加,提高了FA的利用率,加快了体系产生${\rm{CO}}_2^{\cdot-} $的速率,进而增强了Cr(Ⅵ)还原的效率。

    • 初始Cr(Ⅵ)浓度为200 mg·L−1、PS浓度为20 mmol·L−1、FA浓度为40 mmol·L−1时,考察在60 min内,随着初始pH改变,Cr(Ⅵ)去除率的变化趋势,实验结果见图5。反应前后体系pH存在微弱改变,由图5可知,随着pH由2.4升高到9.0时,Cr(Ⅵ)还原效率呈现明显的下降趋势。当pH=2.4时,在50 min内Cr(Ⅵ)可以完全被去除;当pH=9.0时,Cr(Ⅵ)在50 min内的去除率仅为16.8%。这说明UV/PS/FA在酸性条件下具有较好的还原效果,而在中性尤其是碱性条件下,还原性能会受到明显抑制。这是因为FA的pKa=3.75,改变体系pH会影响FA在溶液中的存在形态,即分子态(HCOOH)或离子态(HCOO),两者与${\rm{SO}}_4^{\cdot-} $的反应速率常数存在差异性,FA分子态更容易与${\rm{SO}}_4^{\cdot-} $反应产生${\rm{CO}}_2^{\cdot-} $[20],因此,随着pH的升高,Cr(Ⅵ)还原效率逐渐降低。

    • 图6为初始Cr(Ⅵ)浓度为200 mg·L−1、PS浓度为20 mmol·L−1、FA浓度为40 mmol·L−1,水中常见阴离子Cl${\rm{HCO}}_3^{-} $${\rm{NO}}_3^{-} $对UV/PS/FA体系降解Cr(Ⅵ)的影响,每种离子浓度均为100 mmol·L−1。由图6可知,Cl${\rm{HCO}}_3^{-} $${\rm{NO}}_3^{-} $ 3种离子均会抑制Cr(Ⅵ)的还原去除,在相同浓度条件下,其抑制程度强弱的顺序为${\rm{HCO}}_3^{-} $>${\rm{NO}}_3^{-} $>Cl。当Cl浓度为100 mmol·L−1时,50 min内Cr(Ⅵ)的去除率由100%降低为74.3%,这表明高浓度的Cl对Cr(Ⅵ)降解存在严重的抑制效果。其主要原因是:Cl可以与${\rm{SO}}_4^{-} $反应生成低活性的氯自由基(Cl · )和超氯自由基(${\rm{Cl}}_2^{\cdot-} $),从而减少了体系${\rm{SO}}_4^{-} $的量[23],见式(6)和式(7);同时,生成的${\rm{Cl}}_2^{\cdot-} $会进一步与HCOOH发生反应[24],故Cl抑制了体系中${\rm{CO}}_2^{\cdot-} $的产生,从而进一步抑制了Cr(Ⅵ)的降解。XU等[25]在四氯化碳降解研究中也发现,低浓度Cl存在微弱抑制效果,高浓度Cl的抑制效果更加明显。

      ${\rm{NO}}_3^{-} $投加量是100 mmol·L−1时,50 min内Cr(Ⅵ)去除率降低为41.6%。推断原因是:溶液中${\rm{NO}}_3^{-} $的增加会消耗体系中氧化性自由基${\rm{SO}}_4^{\cdot-} $[26](式(8)),虽然反应产物为硝酸根自由基(${\rm{NO}}_3^{\cdot} $),可以替代SO4·−与HCOOH反应产生主要还原性自由${\rm{CO}}_2^{\cdot-} $[27](式(9)),但增加的反应步骤,大大降低了整体的反应速率,因此,${\rm{NO}}_3^{-} $对Cr(Ⅵ)还原亦表现出抑制作用。

      当体系中${\rm{HCO}}_3^{-} $浓度为100 mmol·L−1时,对体系还原Cr(Ⅵ)的抑制效果最为明显,50 min去除率降低至26.7%。这是由于当溶液中加入${\rm{HCO}}_3^{-} $,会使溶液pH升高,由2.3.2节可知,提高pH不利于Cr(Ⅵ)降解。此外,随着${\rm{HCO}}_3^{-} $浓度的增加,其会与体系产生的${\rm{SO}}_4^{\cdot-} $发生反应并产生具有氧化性的碳酸根自由基(${\rm{CO}}_3^{\cdot-} $)(见式(10)),从而降低${\rm{SO}}_4^{\cdot-} $与FA反应产生${\rm{CO}}_2^{\cdot-} $的概率[28],且过量的${\rm{HCO}}_3^{-} $还可能与${\rm{CO}}_2^{\cdot-} $相互反应产生${\rm{CO}}_3^{\cdot-} $[29](见式(11)),故高浓度${\rm{HCO}}_3^{-} $也会抑制Cr(Ⅵ)的还原。

    • 腐殖酸(HA)是天然水体中的主要有机物[30]。实验中以HA模拟自然水体中的有机物,当Cr(Ⅵ)初始浓度为200 mg·L−1、PS浓度为20 mmol·L−1、FA浓度为40 mmol·L−1时,考察不同浓度HA对Cr(Ⅵ)降解效果的影响,实验结果见图7。由图7可知,当HA浓度为0 mg·L−1时,50 min内Cr(Ⅵ)的去除率为100%;当HA浓度提高到30 mg·L−1时,Cr(Ⅵ)的去除率降低为68.1%。因此,HA会抑制Cr(Ⅵ)的还原。这可能是由于HA是一种天然有机物,会与强氧化性的自由基反应得到矿化[31],故HA的加入会减少${\rm{SO}}_4^{\cdot-} $的量,从而抑制${\rm{CO}}_2^{\cdot-} $的产生,最终降低了Cr(Ⅵ)还原去除速率。

    • 当PS浓度为20 mmol·L−1、FA浓度为40 mmol·L−1时,改变Cr(Ⅵ)初始浓度,考察Cr(Ⅵ)初始浓度对Cr(Ⅵ)去除的影响,实验结果见图8。由图8可知,Cr(Ⅵ)去除率随着Cr(Ⅵ)初始浓度的增加而降低,但UV/PS/FA体系对不同浓度的Cr(Ⅵ)都有很好的去除效果。当Cr(Ⅵ)初始浓度为100 mg·L−1时,20 min内Cr(Ⅵ)去除率就可以到达100%,将Cr(Ⅵ)完全去除,当Cr(Ⅵ)初始浓度提高为300 mg·L−1时,在60 min内的去除率仅为56%。这是因为当PS和FA浓度一定时,单位时间内产生的${\rm{SO}}_4^{\cdot-} $${\rm{CO}}_2^{\cdot-} $的量基本维持不变,${\rm{CO}}_2^{\cdot-} $还原Cr(Ⅵ)的能力也是一定的,随着Cr(Ⅵ)浓度的增加,被还原Cr(Ⅵ)的量与起始Cr(Ⅵ)的量的比值下降,表观去除率变小。

      当初始Cr(Ⅵ)浓度为200、240和300 mg·L−1时,在一定的反应时间内,对Cr(Ⅵ)的还原过程进行反应动力学拟合,拟合结果如图9所示。由图9可知,dC与dt有很好的线性关系,这说明UV/PS/FA降解Cr(Ⅵ)的反应符合零级反应动力学。通过拟合得到Cr(Ⅵ)不同初始浓度下还原速率常数(见表1)。由表1可知,当Cr(Ⅵ)初始浓度为200 mg·L−1、PS浓度为20 mmol·L−1、FA浓度为40 mmol·L−1时,Cr(Ⅵ)还原反应速率常数为78.467 μmol·(L·min)−1。WANG等[32]发现Fe(III)浓度为179.1 μmol·L−1,pH为1.0时,均相光催化还原Cr(Ⅵ)也遵循零级动力学反应方程式,且反应动力学常数仅为0.934 μmol·(L·min)−1,相对而言,UV/PS/FA体系对Cr(Ⅵ)具有更加高效的还原效率。

    • 1)采用UV/PS/FA体系,实现了对高浓度Cr(Ⅵ)的还原处理。当Cr(Ⅵ)初始浓度为200 mg·L−1、PS浓度为20 mmol·L−1、FA浓度为40 mmol·L−1时,在反应50 min后Cr(Ⅵ)基本完全被还原去除。对反应过程中的活性自由基采用ESR技术进行表征,证实了${\rm{CO}}_2^{\cdot-} $的存在。

      2)UV/PS/FA体系在酸性条件下具有较强的还原能力,随着体系pH的升高还原作用呈现明显下降趋势。随着体系中PS浓度的升高,Cr(Ⅵ)去除率逐渐提高。水溶液中存在的HA、Cl${\rm{HCO}}_3^{-} $$ {\rm{NO}}_3^{-}$都会在不同程度对Cr(Ⅵ)的还原产生抑制作用。

      3)对不同初始浓度下Cr(Ⅵ)降解过程进行动力学分析推导,可知其符合零级反应动力学,且初始Cr(Ⅵ)浓度为200、240和300 mg·L−1时对应的反应速率常数分为78.467、70.156和56.577 μmol·(L·min)−1。本研究为Cr(Ⅵ)废水的处理提供了高效的还原方法。